Technical Information for Felrapper Wrapping Machines
Please review the following technical information for Felrapper wrapping machines if you ever experience any issues. If you need clarification on any of these troubleshooting instructions, you are welcome to contact Felrap World, Inc.
Electrical Tests
When electrical tests are necessary, a standard 100V neon circuit tester can be used for the procedures.
Checking the Fuse
To check the fuse, turn the power off, disconnect the red wire from terminal one, and secure it out of the way without touching any metal parts. With the power on, test across terminals three and four. If the tester does not light, replace the fuse.
Checking the Hot Rod
To check the hot rod, turn the power off, disconnect the red wire from terminal one, and secure it out of the way without touching any metal parts. With the power on, test between terminal one and the end of wire disconnected from same terminal. If the tester does not light, replace the hot rod.
Checking the Circuit Board
When you need to check the circuit board, turn the power off, disconnect the red wire from terminal one, and secure it out of the way without touching any metal parts. With the power on, test across terminals one and two. If the tester does not light, replace the circuit board.
If you need additional troubleshooting assistance, please contact our firm in Warren, Rhode Island, online or by phone. We proudly serve clients from around the world.